Products Accessory line

Everything around
the compute

Factory-installed or bundled · one PO · one FAT/SAT pack · one warranty

Accessory lineup: 800G optics, MPO trunk, PDC/busway, UPS bay option, CDU 2xN (1+1)

The container is the product; the accessory line is what makes it turnkey in practice. Optics, fiber, power distribution, the UPS bay, the CDU pair, the dry coolers, the monitoring kit — every line item ships in the same quote, gets pre-tested in the same FAT, and lands under the same warranty. Honest boundary: we don't make optics — transceivers follow your server OEM's qualified list, and we bundle and pre-test them so the fiber plant is certified end-to-end before the pod leaves the factory.

The catalog

Line itemWhat shipsWhy bundle itUsed in
800G opticsOSFP / QSFP-DD transceivers matched to the server QVL, DAC/AOC for in-row linksPre-tested in FAT; fiber plant certified end-to-end at handoverB300 pod · H200 fleet
MPO fiber trunks12/24-fiber factory-terminated trunks, IL/RL test report per trunk, spares kitField termination is the #1 latency for go-live slips; factory trunks close itB300 pod · H200 fleet
PDC / buswayUL 891 power distribution cabinet, feeder columns, branch meteringThe LV feeder lands once — the distribution inside is ours to certifyEvery pod · power chain
UPS bay (option)Modular double-conversion UPS + Li-ion, 5–15 min ride-throughAI training reruns vs enterprise tenancy — you opt in knowingly, +$0.15–0.25MEnterprise-leaning H200 fleets
CDU 2×N (1+1)Two complete liquid CDUs, shared tie-bus + isolation valves, UPS-backed pumps/controlsWhole-unit backup standard — survivor carries full IT ×1.1 [canon, spec book §3.2]FDC-P40-LC
Dry cooler bankExternal V-coil dry coolers sized at 42 °C / 25 °C wet-bulb; adiabatic assist optionTexas summer is a design case — the derate strategy ships in writingEvery pod · WUE ≈ 0
SCADA / DCIM kitIEC 61850 / Modbus / BACnet / SNMP gateway, BMS, leak detection, VESDA + clean agentThe point list stays live to our US operations NOCEvery pod
Spares & consumablesFilters, coolant, QD seals, fan modules — staged in-country48–72 h dispatch target from the chain we controlOperations

Tech behind the line: the three cooling chains decide which cooling items your box carries; the MV→LV power anatomy is what the PDC plugs into; the 800 VDC track is the power bay's swap path. Pricing sits on the pod price ladder — accessory line items are quoted inside it, not as surprise adders after signature.

Bundle it into a pod quote Back to FDC-P40